Test instructions mono board DVD-ASD1
GB 9ASD-1 5.
5. Test instructions mono board DVD-ASD1
5.1 General
Impedance of measuring-equipment should be > 1M
.
Most tests have to be done by software commands.
Together with the software command you will find a Ref.#
nbr. This is the number of the diagnostic nulceus used for
this test. More detailed information can be find in the
chapter “Diagnostic Nuclei”.
Levels: Most measurements are digital measurements.
The high and low levels in this document got to have next
specification:
low : < 0.3V
high : > 3.0V
LOW : < 0.4V
HIGH : > 4.5V
All voltages marked with “stby” have to stay on during
standby.
5.2 General start-up measurements
5.2.1 Supply check:
Pin nbr. Supply
1600-1 3V3
1600-2 3V3
1600-3 +5V0V during STAND BY
1600-4 +5Vstby
1600-5 +6V
1600-6 0V
1600-7 0V
1600-8 0V
1600-9 -8V
1600-10 0V5V during STAND BY
1600-11 +12Vstby
0V
Check the supply currents to be sure there are no large failures
on the board. Before measuring the currents, make sure that
no A/V board, display board or Mercury 1 loader is connected
to the mono board and that the PC interface cable is connected
to the board.
Also check if the servo part gets its power.
Testpoint F608: +3V3
±
5%
Testpoint F101: +9V ±5%
The supply currents can be measured using a Tektronix
AM503B current probe.
Supply power consumption
3V3 400mA ±10%
5V 370mA ±10%
5Vstby < 5mA
-8V 55mA ±10% fluctuation: ±20mA
12Vstby 30mA ±20% fluctuation: ±150mA
5.2.2 Reset check:
The reset circuit is triggered by the stand-by line. First make
sure that the STB_CONT line is HIGH by connecting 5V to
testpoint F505.
Then switch STB_CONT over to LOW and check next timing at
the STI5505 reset input (testpoint F503):
Figure 5-1
T 1 = 150msec ±25% (From 0V to 3V3 -3db)
If the reset input doesn’t go high then check the circuit around
transistor 7501.
5.2.3 Clock check
To check the correct functioning of the STI5505, we first have
to check the presence of all clocks.
All clocks to be measured with 0.02% tolerance.
Clock-name Testpoint Frequency
27M_CLK F051 27MHz
PCM_CLK F566 11.2896MHz
Figure 5-2
PM3392A
ch2
ch1
ch1: dT= 148ms dV=2.41 V
CH1 1.00 V=
CH2 0.2 V= MTB50.0ms- 2.10dv ch2-
1
2
T
T1
RESET TIMING
CL06532065_003.eps
180500
PM3394B
ch1
CH1 2.00 V~ MTB20.0ns ch1+
1
CL06532065_004.eps